Product Identification
Product ID:G 321
MSDS Date:06/07/1994
FSC:8030
NIIN:00N066663
MSDS Number: CBDTV
Responsible Party
CLEVELAND, OH 44104
US
Emergency Phone: 800-626-6527
Info Phone: 800-626-6527
Preparer: JASON E. BARNES
Cage: NOVAG
Contractor
Telephone: 800-626-6527
Cage: NOVAG
Ingredients
DIMETHYL DIPHENYL POLYSILOXANE; (METHYLPHENYL POLYSILOXANE)
CAS: 68083-14-7
Fraction By Weight: 60-90%
OSHA PEL N/K
ACGIH TLV: N/K
STEARIC ACID, LITHIUM SALT; (LITHIUM STEARATE)
CAS: 4485-12-5
RTECS: WI4370000
Fraction By Weight: 15-35%
OSHA PEL N/K
ACGIH TLV: N/K
AREAS W/PROPER PROT EQUIP SUCH AS GOGGS, GLOVES,
RTECS: 9999999ZZ
SOLVS. BE AWARE OF THEIR FLAMMABILITY STATUS. CONSULT
RTECS: 9999999ZZ
USE & DISP OF SOLVS. MAKE SURE THAT CHOICE OF SOLV
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN CONTACT:NOT EXPECTED TO CAUSE
IRRITATION. EYE CONTACT:MAY CAUSE TEMPORARY IRRITATION.
TOXICITY:G-321 HAS NOT BEEN KNOWN TO PRODUCE ANY LASTING HARMFUL
EFFECTS. CONTACT W/EYES MAY CAUSE TRANSITORY IRRITATION WHICH
USUALLY DISAPPEARS INA FEW HOURS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . INGEST:DO NOT INDUCE VOMITING. GET PROMPT MEDICAL
ATTENTION. SKIN:WASH CONTACTED AREAS W/SOAP & WATER. EYE:FLUSH
W/COPIOUS AMO UNTS OF WATER FOR AT LEAST 15 MINUTES. IF CHRONIC
IRRITATION DEVELOPS CONTACT MD.
Fire Fighting
Flash Point Method:COC
Flash Point:>399F,>204C
Extinguishing Media:USE CARBON DIOXIDE OR DRY CHEMICAL ON SMALL FIRES.
USE FOAM & WATER SPRAY FOR LARGE FIRES.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:USE ABSORB MATL TO COLLECT & CONTAIN MATL FOR
DISP. SPILLED SILICONE GREASES & CMPDS WILL CAUSE SLIPPERY CNDTNS.
WIPE UP & CLEAN SPILLS IMMED TO PVNT POSS INJURY. SILICONE GREASES
& CMPDS MAY BE CLEAN ED W/USE OF HYDROPHOBIC SOLVS (NON-POLAR)
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN TEMPERATURES BELOW 100F. KEEP
CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:G-321 MAY BE STORED AT 100F OR BELOW FOR PERIODS UP
TO ONE YEAR. EXTENDED STORAGE LIFE IS PROBABLE, BUT COMPOUND SHOULD
BE CHECKED FOR CONSISTENCY BEFORE USE.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SHOULD BE NEEDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC:SUCH AS CHLORINATED ETHANES, TOLUENE, HEXANE/MINERAL
SPIRITS. THEY ARE GENRLY UNEFFECTED BY HYDROPHILIC SOLVS (POLAR)
SUCH AS ALCOHOLS, KETONES, ETHERS/WATER. WHENEVER SOLVS ARE USED
ALL PR OPER SFTY PRECS MUST BE OBSERVED. IT ISADVISABLE TO CONSIDER
ALL SOLVS AS TOX & USE THEM ONLY IN WELL VENTILATED(ING 3)
Chemical Properties
Spec Gravity:0.99
Solubility in Water:<3%
Appearance and Odor:WHITE TO TAN PASTE; ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR BASES, STRONG OXIDIZING AGENTS. DO NOT USE W/HIGHLY
OXIDATIVE CHEMS SUCH AS LIQ OXYG, CHLORINE/PEROXIDE.
Stability Condition to Avoid:DO NOT USE ON SURFACES TO BE PAINTED.
Hazardous Decomposition Products:HAZARDOUS PRODUCTS FORMED BY FIRE OR
THERMAL DECOMPOSITION: CARBON DIOXIDE, CARBON MONOXIDE, SILICON
DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W ALL APPLICABLE FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.